Snmp tester prtg

Author: m | 2025-04-24

★★★★☆ (4.8 / 2856 reviews)

Download excel password recovery standard

This article applies as of PRTG 22. Debug SNMP issues with SNMP Tester. With SNMP Tester, you can run simple SNMP requests against a device in your network.This test program is based on the SNMP technologies built in to PRTG.

Download gpu z 2.22.0

SNMP PRTG PAESSLER SNMP TESTER

Hi All, I added our Checkpoint Firewall appliances (3 Cluster Nodes) to my PRTG Core Server. Node 01: 10.x.y.2Node 02: 10.x.y.3Node 03: 10.x.y.4Node 01 and Node 03 are fully integrated with all kind of SNMP Sensor but when i want to add a snmp sensor to node 02 i get the following error message in prtg: Could not create SNMP Session (-1114)-2011All Firewall Settings and SNMP Credentials are correct (same as on node 01 and node 03). Now the confusing part: When i test the connection with the snmp-tester from the prtg server its working just fine: ----------------------- New Test -----------------------Paessler SNMP Tester 5.2.3 Computername: TURBONPT01 Interface: 10.21.63.8421.08.2019 12:24:07 (18 ms) : Device: 10.21.65.321.08.2019 12:24:07 (26 ms) : SNMP V321.08.2019 12:24:07 (37 ms) : Uptime21.08.2019 12:24:08 (208 ms) : SNMP Datatype: ASN_TIMETICKS21.08.2019 12:24:08 (219 ms) : -------21.08.2019 12:24:08 (234 ms) : DISMAN-EVENT-MIB::sysUpTimeInstance = 6571140 ( 18 hours 15 minutes )21.08.2019 12:24:08 (283 ms) : SNMP Datatype: ASN_TIMETICKS21.08.2019 12:24:08 (292 ms) : HOST-RESOURCES-MIB::hrSystemUptime.0 = 561809556 ( 65 days )21.08.2019 12:24:08 (301 ms) : DoneAny ideas? best regards, Adrian snmp snmp-error#2003 snmp-error#2011 snmp-sensor

nle background

PRTG Server - no SNMP-Response, but SNMP Tester works

Unable to monitor ASR1001 CPU utilization. I was able to auto - discover 2900 ISRs and clone the CPU sensor to other 2900s but wont work for ASR1000. Does anyone know what the MIB is for cpu on asr1000 cisco-asr mib snmp 3 Replies We found a MIB on the Cisco ftp in the "CISCO-PROCESS-MIB.my", that described some oids including:- 1.3.6.1.4.1.9.9.109.1.1.1.1.7: The overall CPU busy percentage in the last 1 minute period. This object deprecates the object cpmCPUTotal1min and increases the value range to (0..100).- 1.3.6.1.4.1.9.9.109.1.1.1.1.8: The overall CPU busy percentage in the last 5 minute period. This object deprecates the object cpmCPUTotal5min and increases the value range to (0..100).There a lot of oids contained, that might be of use for you. Here is a download link for you. You can use the mib importer, to import the mib into PRTG. Here is a description on how to use the mib importer. Hi there,To add to this question, I'm having difficulties graphing CPU utilization for ASR1001's.When using SNMP walk from a Linux server I get a response and am able to graph from Cacti: $snmpwalk -v2c -c removed 10.209.20.31 1.3.6.1.4.1.9.9.109.1.1.1.1.7SNMPv2-SMI::enterprises.9.9.109.1.1.1.1.7.2 = Gauge32: 11However, when testing with the SNMP Tester I get the same error as in PRTG:2/08/2013 2:37:03 p.m. (1 ms) : Start using SNMP V2c2/08/2013 2:37:03 p.m. (64 ms) : -------2/08/2013 2:37:03 p.m. (64 ms) : Value: No such instance (SNMP error # 223)2/08/2013 2:37:03 p.m. (64 ms) : DoneAny thoughts on the solution?Regards,Dan Which oid did you use

PRTG Server - no SNMP-Response, but SNMP Tester works - Paessler

Hardware from different vendors, whether you’re using PDUs, UPS systems, or environmental sensors from various manufacturers. So you can integrate PRTG into any data center setup without worrying about whether everyone will play well together. Phenomenal alerting power Or maybe just tailor-made alerts for every situation, which is really all a good facility manager needs, right? With PRTG, you’re in control of your alerts. Set custom notifications based on specific thresholds. You can even escalate alerts to different team members depending on the severity, making sure the right person is notified at the right time. Control who sees what when PRTG is For Your Eyes Only, offering granular permissions and access rights management, so you can decide who has access to certain areas of your data center monitoring. It’s great for large teams where different people need access to different information without complicating things. So you can lock it down like Fort Knox or let it all out for anyone who wants to see. Your data center power monitor at a glance – even on the go Set up PRTG in minutes and use it on almost any mobile device.PRTG monitors these vendors and applications in one view! Find the root cause of the problem with our PRTG data center power monitoring solution Real-time notifications mean faster troubleshooting so that you can act before more serious issues occur. PRTG is compatible with all major vendors, products, and systems Explore our preconfigured PRTG sensors for data center power monitoring PRTG comes with more than 250 native sensor types for monitoring your entire on-premises, cloud, and hybrid cloud environment out of the box. Check out some examples below! SNMP Rittal CMC III Hardware StatusThe SNMP Rittal CMC III Hardware Status sensor monitors the overall status of Rittal data center hardware, for example Rittal Computer Multi Control version 3 (CMC III) processing units, Rittal power distribution units (PDU), or Rittal IoT interfaces. It can show the following: Overall device status Attached external sensor status SNMP APC HardwareThe SNMP APC Hardware sensor monitors performance counters on an APC UPS device. It can show the. This article applies as of PRTG 22. Debug SNMP issues with SNMP Tester. With SNMP Tester, you can run simple SNMP requests against a device in your network.This test program is based on the SNMP technologies built in to PRTG. This article applies as of PRTG 22. Debug SNMP issues with SNMP Tester. With SNMP Tester, you can run simple SNMP requests against a device in your network.This test program is based on the SNMP technologies built in to PRTG.

Do PRTG and PRTG SNMP Tester support Octet/HEX Strings?

Hi There,Ive a situation , I have two HP Gen9 servers running Esxi Version 6.7 , as i was adding the iLOs ( which has the same version of firmware ) on PRTG , I could add a "SNMP HP ProLiant Network Interface" on one of them and on the other one with the exact settings i cannot add this sensor and i face with this error : Could not create the sensor SNMP HP ProLiant Network Interface on device xxxxx.what problem could cause this issue?thank you. gen9 hp ilo 5 Replies Hello,Can you download our SNMP Tester from the following link?SNMP TesterThen use it to test against that second iLO host? Just check to see if you can get System Uptime to start with.If you can, let me know, and I'll send you a walk script to check the OIDs we monitor in the iLOs.Thanks!Benjamin DayPaessler Support Hi there,which method should i chose as a request type in SNMP Tester?as long as i understand this is the " Read Device Uptime " result :----------------------- The iLO With Problem -----------------------Paessler SNMP Tester 5.2.3 Computername: x.x.x.x Interface: ()2/26/2019 9:54:25 AM (4 ms) : Device: x.x.2.142/26/2019 9:54:25 AM (7 ms) : SNMP V2c2/26/2019 9:54:25 AM (11 ms) : Uptime2/26/2019 9:54:25 AM (22 ms) : SNMP Datatype: ASN_TIMETICKS2/26/2019 9:54:25 AM (30 ms) : -------2/26/2019 9:54:25 AM (35 ms) : DISMAN-EVENT-MIB::sysUpTimeInstance = 26225807 ( 3 days 0 hours 50 minutes )2/26/2019 9:54:25 AM (49 ms) : SNMP Datatype: SNMP_EXCEPTION_NOSUCHOBJECT2/26/2019 9:54:25 AM (54 ms) : HOST-RESOURCES-MIB::hrSystemUptime.0 = No such object (SNMP error # 222) ( 0 seconds )2/26/2019 9:54:25 AM (60 ms) : Done----------------------- The Correct iLo -----------------------Paessler SNMP Tester 5.2.3 Computername: x.x.x.x Interface: ()2/26/2019 9:55:03 AM (13 ms) : Device: x.x.2.282/26/2019 9:55:03 AM (20 ms) : SNMP V2c2/26/2019 9:55:03 AM (27 ms) : Uptime2/26/2019 9:55:05 AM (2044 ms) : SNMP Datatype: ASN_PRIMITIVE2/26/2019 9:55:05 AM (2054 ms) : -------2/26/2019 9:55:05 AM (2065 ms) : DISMAN-EVENT-MIB::sysUpTimeInstance = No response (check: firewalls, routing, snmp settings of device, IPs, SNMP version, community, passwords etc) (SNMP error # -2003) ( 0 seconds )2/26/2019 9:55:07 AM (4090 ms) : SNMP Datatype: ASN_PRIMITIVE2/26/2019 9:55:07 AM (4099 ms) : HOST-RESOURCES-MIB::hrSystemUptime.0 = No response (check: firewalls, routing, snmp settings of device, IPs, SNMP version, community, passwords etc) (SNMP error # -2003) ( 0 seconds )2/26/2019 9:55:07 AM (4108 ms) : Done Hello,Is there any difference in iLO version between these two?Benjamin DayPaessler Support Hi,No , both of them are iLO 4 , and even the firmwares are the same , the version of Snmp which i've been configured is V2 as well. Thats very weird as one replies with Timeticks, and the other replies with Primitive to Uptime requests. But you say both

Do PRTG and PRTG SNMP Tester support Octet/HEX - Paessler

Number of devices while also taking full advantage of Observium’s network mapping features. The Observium network monitoring platform features automatic discovery of connected devices, ensuring that the map of your network is up to date. This way, users can account for any new devices as they connect to the network.OpmantekTool: Opmantek NMISRelated Products: NMIS Professional, Virtual Appliance PackageDescription: Opmantek Network Management Information System is an open source network management solution for scalable network performance and device status monitoring. NMIS has support for 10,000 vendors and classifies network events based on their business impact. NMIS is included in Opmantek’s NMIS professional bundle, which also includes opCharts for charting performance through customizable dashboards and opReports for analyzing performance data and generating reports on this data.Pandora FMSTool: Pandora FMS CommunityRelated Products: Pandora FMS EnterpriseDescription: Pandora FMS Community is an open source monitoring tool that helps companies observe their entire IT infrastructure. It not only features network monitoring capabilities, but also Windows and Unix servers and virtual interfaces. For networks, Pandora FMS contains features such as ICMP polling, SNMP support, network latency monitoring, and system overload. You can also install agents on devices to observe factors like device temperature and overheating, as well as logfile occurrences.PaesslerTool: Paessler PRTG 100Related Products: NewFlow Tester, SNMP TesterDescription: Paessler is a network monitoring provider that offers a free version of their solution: PRTG 100. Paessler offers this tier of their monitoring program that supports 100 devices on a single network. PRTG monitoring features include tracking network traffic, applications, data packets, and bandwidth. The software functions as an all-in-one monitoring suite which is also able to monitor cloud environments, virtual machines, and hardware in addition to a company’s network.PrometheusTool: PrometheusDescription: Prometheus is an open source monitoring solution focused on data collection and analysis. It allows users to set up

Diagnosticar error en SNMP con PRTG - Paessler SNMP Tester

It all with our firewall analyzer PRTG. What firewall analysis looks like in PRTG Diagnose network issues by continuously tracking and analyzing firewall devices and logs. Show firewall traffic, CPU and memory usage, uptime, bandwidth monitoring stats, user authentication info, firewall changes, and other key metrics in real time. Visualize monitoring data in clear graphs and dashboards to identify problems more easily. Gain the overview you need to troubleshoot all kinds of issues with firewall security and network performance. Device tree view of the complete monitoring setup Preconfigured Fortigate System Statistics sensor in PRTG Custom PRTG dashboard for keeping an eye on the entire IT infrastructure Start analyzing your firewall devices with PRTG and see how it can make your network more reliable and your job easier. IT experts agree: Paessler PRTG is a great solution for IT infrastructure monitoring “All-around winning network monitor” “The real beauty of PRTG is the endless possibilities it offers” “PRTG Network Monitor is very hard to beat” Enjoy industry-leading compatibility with the PRTG Comprehensive firewall traffic analysis PRTG includes native sensors for NetFlow, sFlow, and jFlow to get detailed information about the traffic on your firewalls – sorted by IP address, port, and protocol. But even if your device does not support flow monitoring, PRTG includes the SNMP Traffic v2 sensor and the Packet Sniffer sensor to get the information you need. Out-of-the-box FortiGate monitoring Our two built-in sensors for monitoring FortiGate firewalls include the FortiGate VPN Overview sensor, which helps you track your SNMP Cisco ASA VPN Connections. The FortiGate System Statistics sensor can, for example, determine if the device is in "conserve" mode, a self-protection measure that is activated when the system detects memory shortage. Built-in SonicWall monitoring PRTG also comes with two built-in sensors for monitoring SonicWall devices. The SNMP SonicWall System Health sensor helps you keep an eye on the overall health of your firewall. The SNMP SonicWall VPN Traffic sensor gives you an overview of the IPsec VPN traffic on your SonicWall device such as the number of encrypted and decrypted packets per second. Real-time alerts and notifications PRTG notifies you immediately if your firewall is down so you can quickly determine the cause of the interruption and how to get the firewall back up. You can also customize alerts for different escalation scenarios. Define granular notification triggers, and choose to be notified via email, SMS, push notification, Teams. This article applies as of PRTG 22. Debug SNMP issues with SNMP Tester. With SNMP Tester, you can run simple SNMP requests against a device in your network.This test program is based on the SNMP technologies built in to PRTG. This article applies as of PRTG 22. Debug SNMP issues with SNMP Tester. With SNMP Tester, you can run simple SNMP requests against a device in your network.This test program is based on the SNMP technologies built in to PRTG.

Comments

User9242

Hi All, I added our Checkpoint Firewall appliances (3 Cluster Nodes) to my PRTG Core Server. Node 01: 10.x.y.2Node 02: 10.x.y.3Node 03: 10.x.y.4Node 01 and Node 03 are fully integrated with all kind of SNMP Sensor but when i want to add a snmp sensor to node 02 i get the following error message in prtg: Could not create SNMP Session (-1114)-2011All Firewall Settings and SNMP Credentials are correct (same as on node 01 and node 03). Now the confusing part: When i test the connection with the snmp-tester from the prtg server its working just fine: ----------------------- New Test -----------------------Paessler SNMP Tester 5.2.3 Computername: TURBONPT01 Interface: 10.21.63.8421.08.2019 12:24:07 (18 ms) : Device: 10.21.65.321.08.2019 12:24:07 (26 ms) : SNMP V321.08.2019 12:24:07 (37 ms) : Uptime21.08.2019 12:24:08 (208 ms) : SNMP Datatype: ASN_TIMETICKS21.08.2019 12:24:08 (219 ms) : -------21.08.2019 12:24:08 (234 ms) : DISMAN-EVENT-MIB::sysUpTimeInstance = 6571140 ( 18 hours 15 minutes )21.08.2019 12:24:08 (283 ms) : SNMP Datatype: ASN_TIMETICKS21.08.2019 12:24:08 (292 ms) : HOST-RESOURCES-MIB::hrSystemUptime.0 = 561809556 ( 65 days )21.08.2019 12:24:08 (301 ms) : DoneAny ideas? best regards, Adrian snmp snmp-error#2003 snmp-error#2011 snmp-sensor

2025-04-06
User2212

Unable to monitor ASR1001 CPU utilization. I was able to auto - discover 2900 ISRs and clone the CPU sensor to other 2900s but wont work for ASR1000. Does anyone know what the MIB is for cpu on asr1000 cisco-asr mib snmp 3 Replies We found a MIB on the Cisco ftp in the "CISCO-PROCESS-MIB.my", that described some oids including:- 1.3.6.1.4.1.9.9.109.1.1.1.1.7: The overall CPU busy percentage in the last 1 minute period. This object deprecates the object cpmCPUTotal1min and increases the value range to (0..100).- 1.3.6.1.4.1.9.9.109.1.1.1.1.8: The overall CPU busy percentage in the last 5 minute period. This object deprecates the object cpmCPUTotal5min and increases the value range to (0..100).There a lot of oids contained, that might be of use for you. Here is a download link for you. You can use the mib importer, to import the mib into PRTG. Here is a description on how to use the mib importer. Hi there,To add to this question, I'm having difficulties graphing CPU utilization for ASR1001's.When using SNMP walk from a Linux server I get a response and am able to graph from Cacti: $snmpwalk -v2c -c removed 10.209.20.31 1.3.6.1.4.1.9.9.109.1.1.1.1.7SNMPv2-SMI::enterprises.9.9.109.1.1.1.1.7.2 = Gauge32: 11However, when testing with the SNMP Tester I get the same error as in PRTG:2/08/2013 2:37:03 p.m. (1 ms) : Start using SNMP V2c2/08/2013 2:37:03 p.m. (64 ms) : -------2/08/2013 2:37:03 p.m. (64 ms) : Value: No such instance (SNMP error # 223)2/08/2013 2:37:03 p.m. (64 ms) : DoneAny thoughts on the solution?Regards,Dan Which oid did you use

2025-04-07
User1799

Hi There,Ive a situation , I have two HP Gen9 servers running Esxi Version 6.7 , as i was adding the iLOs ( which has the same version of firmware ) on PRTG , I could add a "SNMP HP ProLiant Network Interface" on one of them and on the other one with the exact settings i cannot add this sensor and i face with this error : Could not create the sensor SNMP HP ProLiant Network Interface on device xxxxx.what problem could cause this issue?thank you. gen9 hp ilo 5 Replies Hello,Can you download our SNMP Tester from the following link?SNMP TesterThen use it to test against that second iLO host? Just check to see if you can get System Uptime to start with.If you can, let me know, and I'll send you a walk script to check the OIDs we monitor in the iLOs.Thanks!Benjamin DayPaessler Support Hi there,which method should i chose as a request type in SNMP Tester?as long as i understand this is the " Read Device Uptime " result :----------------------- The iLO With Problem -----------------------Paessler SNMP Tester 5.2.3 Computername: x.x.x.x Interface: ()2/26/2019 9:54:25 AM (4 ms) : Device: x.x.2.142/26/2019 9:54:25 AM (7 ms) : SNMP V2c2/26/2019 9:54:25 AM (11 ms) : Uptime2/26/2019 9:54:25 AM (22 ms) : SNMP Datatype: ASN_TIMETICKS2/26/2019 9:54:25 AM (30 ms) : -------2/26/2019 9:54:25 AM (35 ms) : DISMAN-EVENT-MIB::sysUpTimeInstance = 26225807 ( 3 days 0 hours 50 minutes )2/26/2019 9:54:25 AM (49 ms) : SNMP Datatype: SNMP_EXCEPTION_NOSUCHOBJECT2/26/2019 9:54:25 AM (54 ms) : HOST-RESOURCES-MIB::hrSystemUptime.0 = No such object (SNMP error # 222) ( 0 seconds )2/26/2019 9:54:25 AM (60 ms) : Done----------------------- The Correct iLo -----------------------Paessler SNMP Tester 5.2.3 Computername: x.x.x.x Interface: ()2/26/2019 9:55:03 AM (13 ms) : Device: x.x.2.282/26/2019 9:55:03 AM (20 ms) : SNMP V2c2/26/2019 9:55:03 AM (27 ms) : Uptime2/26/2019 9:55:05 AM (2044 ms) : SNMP Datatype: ASN_PRIMITIVE2/26/2019 9:55:05 AM (2054 ms) : -------2/26/2019 9:55:05 AM (2065 ms) : DISMAN-EVENT-MIB::sysUpTimeInstance = No response (check: firewalls, routing, snmp settings of device, IPs, SNMP version, community, passwords etc) (SNMP error # -2003) ( 0 seconds )2/26/2019 9:55:07 AM (4090 ms) : SNMP Datatype: ASN_PRIMITIVE2/26/2019 9:55:07 AM (4099 ms) : HOST-RESOURCES-MIB::hrSystemUptime.0 = No response (check: firewalls, routing, snmp settings of device, IPs, SNMP version, community, passwords etc) (SNMP error # -2003) ( 0 seconds )2/26/2019 9:55:07 AM (4108 ms) : Done Hello,Is there any difference in iLO version between these two?Benjamin DayPaessler Support Hi,No , both of them are iLO 4 , and even the firmwares are the same , the version of Snmp which i've been configured is V2 as well. Thats very weird as one replies with Timeticks, and the other replies with Primitive to Uptime requests. But you say both

2025-03-26
User8160

Number of devices while also taking full advantage of Observium’s network mapping features. The Observium network monitoring platform features automatic discovery of connected devices, ensuring that the map of your network is up to date. This way, users can account for any new devices as they connect to the network.OpmantekTool: Opmantek NMISRelated Products: NMIS Professional, Virtual Appliance PackageDescription: Opmantek Network Management Information System is an open source network management solution for scalable network performance and device status monitoring. NMIS has support for 10,000 vendors and classifies network events based on their business impact. NMIS is included in Opmantek’s NMIS professional bundle, which also includes opCharts for charting performance through customizable dashboards and opReports for analyzing performance data and generating reports on this data.Pandora FMSTool: Pandora FMS CommunityRelated Products: Pandora FMS EnterpriseDescription: Pandora FMS Community is an open source monitoring tool that helps companies observe their entire IT infrastructure. It not only features network monitoring capabilities, but also Windows and Unix servers and virtual interfaces. For networks, Pandora FMS contains features such as ICMP polling, SNMP support, network latency monitoring, and system overload. You can also install agents on devices to observe factors like device temperature and overheating, as well as logfile occurrences.PaesslerTool: Paessler PRTG 100Related Products: NewFlow Tester, SNMP TesterDescription: Paessler is a network monitoring provider that offers a free version of their solution: PRTG 100. Paessler offers this tier of their monitoring program that supports 100 devices on a single network. PRTG monitoring features include tracking network traffic, applications, data packets, and bandwidth. The software functions as an all-in-one monitoring suite which is also able to monitor cloud environments, virtual machines, and hardware in addition to a company’s network.PrometheusTool: PrometheusDescription: Prometheus is an open source monitoring solution focused on data collection and analysis. It allows users to set up

2025-04-08

Add Comment